Homepage | Home | Bookmarke
Member

Baicheng Medical Technology Co.Ltd


Products
  • No Category
Search
 

Friends links
  • No link
You are here: Home » Products » PMV-800B Veterinary Monitor
PMV-800B Veterinary Monitor
Click image to view full size image
Product: Views:129PMV-800B Veterinary Monitor 
Unit price: Negotiable
MOQ:
Quantity:
Delivery date: Since the payment date Days delivery
Valid until: Long-term effective
Last updated: 2017-10-25 06:57
  Inquiry
Details
Feature: 12’’1 high resolution color TFT LCD display . One level menu , easy to use . Maximum 720 hours tabular and graphic trends of all parameters. Built –in thermal recorder and two batteries capacity. Suitable for adult , pediatric, neonatal patient . 13 type arrhythmic analysis , ST segment analysis , pacemaker detection. Anti-ESU , anti-defibrillator. oxyCRG dynamic view and short trend coecist display , nurse call system . standard network interface , can connect to the central monitor system . Standard: 12.1 LCD , 5 ECG leads , RESP , NIBP,PR , SPO2, 2-TEMP , Rechargeable battery . Optional : Thermal recorder , 2-IBP, ETCO2 multi-gas , touch screen. Specifications : ECG Lead mode : 3/5 leads Gain : ×0.25 , ×0.5, ×1, ×2, auto Heat rate : 15-350 bpm Accuracy :±1% Resolution : 1bpm ST segment range : -2.0mV-+2.0mV ARR detecting :yes Pacemaker : yes Electrode offset potential : ±300mV Bandwidth Surgery: 1Hz-15Hz Monitor : 0.5Hz-35Hz Diagnostic :0.05Hz-100Hz SPO2: Measuring and alarm range : 0%-100% Resolution :1% Accuracy :70%-100%±2% , 0%-69% unspecified Actualization interval : about 1 sec. Alarm delay : 10sec. PULSE RATE: Measuring and alarm range:20bpm-300bpm Resolution :1bpm Accutacy:2bpm IBP: Label :ART,PA,CVP,RAP,LAP,ICP,P1,P2 Measuring and alarm range ART:0mmHg-300mmHg PA:-6mmHg-120mmHg CVP/RAP/LAP/ICP:-10mmHg-40mmHg P1/P2:-10mmHg-300mmHg Press sensor Sensitivity :5Uv/v/mmHg Resolution:1mmHg Accuracy :2% or 1mmHg ,which great Actualization interval : about 1 secretary RESPIRATION: Method :impedance between R-F(RA-LL) Base line impedance range :0kΩ-2.5 kΩ Bandwidth :0.3 Hz-2.5Hz Measuring range : 0rpm -150rpm Resolution :1rpm Accuracy :2rpm Apnea alarm :10s -40s NIBP: Word mode : manual , auto ,continuous Measuring period in STAT mode: 5Min Pulse rate range :40bpm -240bpm Measurement types :SYS,DIA,MEAN Measuring range Adult mode SYS:40mmHg-270mmHg DIA:10mmHg-215mmHg MEAN:20mmHg-165mmHg Pediatric mode SYS:40mmHg -200mmHg DIA:10mmHg-150mmHg MEAN: 20mmHg-165mmHg Neonatal mode SYS :40mmHg-135mmHg DIA:10mmHg-100mmHg MEAN :20mmHg-110mmHg Resolution pressure:1mmHg Accuracy pressure maximum mean error :5mmHg Maximum standard deviation :8mmHg Overpressure protection Adult mode :2973mmHg Prediatric mode :2403mmHg Neonatal mode :1473mmHg TEMPERATURE: Channel:2 Measuring and alarm range :0℃-5℃ Resolution :0.1 ℃ Accuracy : 0.1 ℃ Actualization interval :about 1 sec Average time constant:<10sec
Inquiry